SOLAR INVERTER HYBRID KENIKA EAH 1000W
Brands Kenika
Product Code: EAH 1000W
Dimensions (L x W x H): 55 x 46 x 28 (Centimeter)
Weight: 21 Kilogram
Rp4,100,000.00
Product details of SOLAR INVERTER HYBRID KENIKA EAH 1000W
Description
Sistem ini juga mempunyai kemampuan paling lengkap untuk menghasilkan tenaga listrik sendiri.
Cara kerja sistem Hybrid On-Grid adalah energi matahari dirubah ke tegangan DC oleh modul PV, kemudian dialirkan ke baterai dengan lebih dahulu melalui inverter Hybrid On-Grid. Inverter Hybrid On-Grid berfungsi untuk merubah tegangan DC ke tegangan AC, melakukan kontrol pengisian pada baterai, melakukan kontrol dari baterai ke jaringan listrik saat terjadi listrik PLN padam, serta melakukan sinkronisasi frekuensi, phase dan sinewave murni saat masuk jaringan PLN.
Specifications:
Model | EAH 1000W |
Rated Power (KW) | 1 |
Output PF | 1 |
DC Voltage | 48Vdc |
Piece/Cell | 4*12V / 24*2V |
Working Mode | Grid-tie mode / anti-flow back can be set |
Time Control | Energy saving priority / power supply priority /AC charging time can be controlled |
PV INPUT | |
Max input voltage | 150Vdc |
Optimum operating voltage | 65 - 110Vdc |
The maximum conversion efficiency | ≥ 97% |
Max charging current | 25A |
Recommended maximum PV power | 1500W |
AC INPUT | |
Input voltage range | Single phase 230V (-20% ~ +15%) |
Rated frequency | 50 / 60Hz |
Frequency range | 50 / 60Hz ± 6% |
Power factor | ≥ 0.98 |
Max charging current | 20A |
INVERTER | |
Inverter voltage | 230V (220V / 240V can set) |
Output voltage accuracy | ± 3% grid off, -20% ~ +15% (grid tied) |
Transient recovery time | ≤ 60ms |
Fixed frequency | Automatically be the same frequency as the grid input |
Crest factor | 3 : 1 (Ipeak / Irms) |
Wave | Pure Sine Wave |
THD liner load | ≤ 3% |
Overload | ≥ 110% / 125% / 150% / 180% 4mins / 1min / 5s / 20ms transfer to bypass or shutdown (shutdown when AC not available) |
0.1s short circuit current | 3 times rated current |
Max efficiency % | ≥ 85% |
BATTERY MANAGEMENT | |
Battery type setting | Lithium / lead acid battery can be set by customer |
Battery setting | Battery number can be set |
Discharge depth setting | Yes |
Float charging voltage | 56Vdc |
End of discharge | 42Vdc |
Charging current | Lead acid battery : 0.05 C -- 0.3 C; lithium battery : 0.1 C -- 1.0 C; can be set |
Battery intelligent management | Battery bank automatically float charging, automatically temperature compensation |
TRANSFER TIME | |
Power off mode -- grid off mode | ≤ 2s |
Grid off mode -- grid tied mode | ≤ 10ms |
Grid tied mode -- grid off mode | ≤ 10ms |
COMMUNICATION | |
Remote control | Transfer to bypass, transfer to inverter, shut down |
Computer interface | RS232 / USB / RS485 (optional) / SNMP (optional) |
ENVIRONMENT | |
Operating temperature | 0 -- 45⁰C |
Max relative humidity | 95% (non condensed) |
Height | 1000m, rated power (100m higher, 1 % derated) Max 4000m |
OTHERS | |
Cooling | Forced cooling (fans speed change with load level) |
Noise | ≤ 50 dB (1 m varies with load and temperature) |
(MTBF) | 200.000 hours |
IP class (EN60529) | IP 21 |