FEATURES
-High Frequency On-line double conversion technology
-DSP (Digital Signal Processors) control technology
-Active power factor correction (APFC), input power factor up to 0.99
-Output power factor 0.9
-Wide input voltage range (110V ~ 300VAC) and frequency range (40 ~ 70Hz)
-Auto sensing frequency
-50/60Hz frequency conversion
-Cold start
-Rear ventilation design and variable speed fan
-Effective software and hardware protection
-Quick and stable charging, 90% capacity restored in 4h
-Linear derating in low voltage input reducing battery discharging times
-Settable delayed start when power is restored
-Advanced battery management (ABM)
-Multiple functions settable via LCD : Output voltage, EOD, auto-start, bypass mode, ECO mode, and frequency conversion
mode
-Multi-platform communications : RS232 (standard), SNMP (Optional)

SPECIFICATIONS :
MODEL : RU-2000
Capacity : 2kVA/1800W
INPUT
Rated Voltage : 208/220/230/240 VAC
Voltage Range : 110~176 VAC (Linear derating between 50% and 100% load); 176~280 VAC (no derating); 280~300 VAC (derating
50%)
Frequency : 40~70Hz (auto-sensing)
Power Factor : ≥ 0.99
Bypass Voltage Range : -25% ~ +15% (settable)
Total Harmonic Distortion : ≤ 6%
OUTPUT
Voltage : 208/220/230/240 VAC (settable via LCD)
Voltage Regulation : ± 1%
Frequency : 45~55Hz or 55~65Hz (synchronized range); 50/60Hz ± 0.1Hz (battery mode)
Waveform : Sinusoidal
Power Factor : 0.9
Total Harmonic Distortion (THDv) : ≤ 2% (linear load); ≤ 5% (non-linear load)
Crest Factor : 3:1
Overload : 105% ~ 125% for 1 min, 125% ~ 150% for 30s, > 150% for 300 ms
BATTERIES
DC Voltage : 48V
Inbuilt Battery : 4 x 9Ah
Charging current (max.) : 1A
Recharger Time : 90% capacity restored in 3 hours
SYSTEM
Efficiency : ≥ 91% (Mains Mode; ≥ 86% (Battery Mode); ≥ 96% (ECO Mode)
Transfer Time : Mains mode to battery mode : 0ms; Inverter mode to bypass mode : 4ms (typical)
Protections : Short-circuit, overload, overtemperature, battery discharge protection and fan testing protection
Communications : RS232 (standard), SNMP (Optional)
Display : LCD + LED
Standards : EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-
5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 62040-1
OTHERS
Operating Temperature : 0°C ~ 40°C
Storage Temperature : -25°C ~ 55°C (without batteries)
Relative humidity : 0~95% (non-condensing)
Altitude : ≤ 1000m, derating 1% for each additional 100m
IP rating : IP20
Noise level at 1m : ≤50dB
Dimensions (WxDxH)(mm) : 440 x 430 x 88
Packaged Dimensions (WxDxH)(mm) : 545 x 560 x 201
Net Weight (Kg) : 19
Gross Weight (Kg) : 22